Mfg Part Number: 179004-2502 | Alternate P/N: 1790042502 | Manufacturer: Julie Research Laboratories Inc |
NSN : 5905-00-082-0174 | Item Name : resistor fixed wire | CAGE Code : 07062 |
FSC : 5905 Resistors |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -10.0 TO 10.0 |
AAPP | ELECTRICAL RESISTANCE | 25.000 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -0.050 TO 0.050 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 55.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 85.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -5.0 TO 65.0 |
AAQZ | INCLOSURE METHOD | HERMETICALLY SEALED |
AARB | TERMINAL TYPE | TAB, SOLDER LUG |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.375 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0.562 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.625 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.333 FREE AIR |
AFWW | TERMINAL WIDTH | 0.188 INCHES NOMINAL |
STYL | STYLE DESIGNATOR | RADIAL TERMINAL EACH END |
TEST | TEST DATA DOCUMENT | 50222-179004 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |